欢迎光临北京锐毅行科技北京赛车pk拾开奖直播官方网站!
 
北京锐毅行科技北京赛车pk拾开奖直播
其他电源
电源分配板,MON02 ,PDM5
  • 电源分配板,MON02 ,PDM5

电源分配板 电源分线器(可监控型 输出状态,带报警信号)


Montored Power Distribution Board 电源分配板(可监控型 DC12V DC24V AC24V)

价格:面议

Features

     User friendly solution to low voltage power distribution

     State-of-the-art SMD technology

     10 Individual fused and monitored outputs

     Operating voltage 12-24V AC or DC

特征

•用户友好的低压配电解决方案

•先进的SMD技术

10个单独融合和监控的输出

•工作电压12-24V ACDC12-24

Specifications

  Model: Mon 02

  Input Voltage:  12-24V AC or DC

 Output:      10 x fused and monitored outputs

Total Current:  10A Max

  Relay Rating: 3A@0-250V AC or 30V DC


Size:   110 x 93mm

 产品规格

 型号:Mon 02
输入电压:12-24V ACDC

输出:10个融合和监控输出(继电器报警信号输出)

总电流:10A最大

继电器额定值:3A @ 0-250V AC或 30V DC

尺寸:110 x 93mm

Operation Voltage Jumper Setting

 Mon 02 May be used for use 12-24V AC or DC devices and ships from the factory set for 24V AC for operation.

 If 12VDC operation is desired, simply change the Jumper to 12V DC.

 工作电压跳线设置

 Mon 02可用于使用12-24V交流或直流设备,出厂默认设置的24V AC运行。

 如果需要12VDC操作,只需将跳线更改为12V DC

 Common Fault Relay

 

Mon 02 includes a common fault output relay (rated at 1A) to drive external devices, such as alarm panels, sounders and DVR alarm inputs, ensuring that failure of any individual circuit does not go unnoticed.

 

During normal operation all green circuit status LEDs 9 will be lit. In the event of a fuse failure, the corresponding circuit status LED will extinguish, the Common Fault Relay 7 will change state and the Common LED 8 will light。

 

 When the fault is rectified and the fuse replaced, LEDs & Relay will return to normal。

故障输出继电器

 Mon 02包括一个常见故障输出继电器(额定值为3A),以驱动外部设备,如报警面板,发声器和DVR报警输入,确保任何单独电路的故障不会被忽视。

 在正常操作期间,所有绿色电路状态LED 9将亮起。 在保险丝故障的情况下,相应的电路状态指示灯将熄灭,公共故障继电器7将改变状态,通用LED 8将点亮。

 当故障整流并更换保险丝时,LED和继电器将恢复正常。

 详细说明书下载 (英语en)mon02.pdf